Specifications
DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-69
CO Line Group Directory Number Swapping
Directory swapping is provided to further customize directory numbers to specific system resources within resource
categories. In this case, the Directory Numbers assigned to CO Line Groups in Flexible Numbering Plans can be
adjusted (if required) to meet the individual resource structure needs for the application.
For instance: the Directory Number for CO Line Group 1 is defaulted to “9” and the Directory Number for CO Line
Group 2 is defaulted to “800.” These two Directory Numbers can be swapped using the Directory Number Swapping
utility if the operation is to access CO Line Group 2 using the directory number “9.”
Programming Abstract
Use CO Line Group Directory Number Swapping to assign the directory number to a specific CO Line
Group.
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
• Enter Database Administration using the feature code
!+* and then enter the DB Admin password
“
++++++++.” (Note: This eight-character password can be changed.)
• Press [
show
showshow
show]. The DB Item Select screen displays.
Enter into CO Line Group Directory Swapping (07-01-01~08-04):
• Input 07-01-0g-04 (where “g” = the CO Line Group number, 1-8).
• Press [show
showshow
show]. The current directory number assigned to this CO Line Group displays.
• Press [show
showshow
show] to swap this directory number with another CO Line group directory number. (9, 800-809).
• Input the directory number that is to be used to access this CO Line Group. (Note: The selected number
must be assigned to this system resource in Flexible Numbering Plan.)
• Press [save
savesave
save]. The data is stored.
• Press the Volume button (up or down) to return to the Database Item Select screen or press [next
nextnext
next] to
enter another CO Line Group number for which the directory number is to be swapped.
• Continue making other programming changes or exit the programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
• Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
• Press any key at the program title page (as it requests) to enter the Main Menu.
• Select PC-DBA from the main menu.
• Select Programming from the PC-DBA menu. Then press
«.
• Use ¢£¤¥ to highlight “CO Line Application.” Then press «.
• Use
¢£¤¥ to highlight “CO Line Group Directory Number Swapping.” Then press «. The current
CO Line Group numbers and the assigned directory number are displayed.
• Use ¢£¤¥ to highlight the appropriate CO Line Group under the column “DIR # Swapping.” Then
press
«.
• Input the CO Line Group Directory Number for this CO Line Group.
• Press
«. The database item is temporarily stored.