Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-65
c) Tenant Group programming of extensions and CO Lines also dictates which CO Lines an extension can
access. See Tenant Group.
Default Settings
All DX-80 extensions are allowed access to all equipped (hardware installed) CO Lines.
All CO Lines are assigned in Tenant Group 1. (Range is 1-3.)
All CO Lines are assigned in CO Line Group 1. (Range is 1-8.)
Programming Abstract
Program the required extensions for Line (CO Line) Access per CO Line.
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
Enter Database Administration using the feature code
!+* and then enter the DB Admin password
++++++++.” (Note: This eight-character password can be changed.)
Press [
show
showshow
show]. The DB Item Select screen displays.
Program extensions for CO Line Access. (01-101~156-23-01~16):
Enter 01-xxx-23-yy to program “xxx” Extension for “yy” CO Line access.
Press [
save
savesave
save]. This advances to CO Line Access for extension “xxx” and CO “yy.”
Press [chg
chgchg
chg] until the appropriate value for this database item displays (Y/N).
Press
the Volume button (up or down) to return to the DB Item Select screen and input another
extension and CO Line
Or…
Press [
back
backback
back] or [next
nextnext
next] to select the previous or next sequential CO Line for the selected extension.
Press [chg
chgchg
chg] until the appropriate value for this database item displays.
When finished programming CO Line Access, press
the Volume button (up or down) to return to the DB
Item Select screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press
«.
Program CO Line Access:
Use
¢£¤¥ to highlight “Extension.” Then press «.
Use ¢£¤¥ to highlight “Line Assignment.” Then press «. (Notice the display header “Extension –
[1/05].” The “[1/05],” indicates that this is the first of five pages for this database screen. Page 1 is extension
ports 1-14 (Extensions 101-114).)
Use the
³ and ´ buttons on the PC keyboard to select the page for the extension(s) to be programmed.