Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-61
Programming via the DET (Digital Extension Terminal)
Note: [back
backback
back], [next
nextnext
next], [show
showshow
show], [chg
chgchg
chg], [bksp
bkspbksp
bksp], and [save
savesave
save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
Enter Database Administration using the feature code
!+* and then enter the DB Admin password
++++++++.” (Note: This eight-character password can be changed.)
Press [
show
showshow
show]. The DB Item Select screen displays.
Program Extension COS per Extension and system operating mode (Day/Evening) (Index 01-101~156,
where “101~156” = the Extension directory number):
Enter 01-101-05 to program Extension 101 Day COS. (COS can be 0-7.)
Or…
Enter 02-101-06 to program Extension 101 Evening COS. (COS can be 0-7.)
Enter 02-101-06 to program Extension 101 Evening COS. (COS can be 0-7.)
Press [
save
savesave
save]. This advances to the selected database item.
Press [chg
chgchg
chg] until the appropriate OCS displays.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu.
Use
¢£¤¥ to highlight “Extension.” Then press «.
Use ¢£¤¥ to highlight “Category 1.” Then press «.
Program Extension COS as required:
Use
¢£¤¥ to highlight “Day Class” or “Eve Class.”
Press « until the appropriate COS displays.
Continue programming other database items as required.
When you have completed all changes, press the
° (escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Press N” to abort changes and leave all data unchanged.
Press Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?
Press N” to abort changes and leave all data unchanged.
Press Y” (yes) to continue with the save operation.
Press
° (escape) again to return to the Database Programming menu.
Continue making other programming changes or exit PC-DBA programming.