Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-58
Program CID codes required for seamless CID callback operations in the DX-80:
Input 03-25 to program the International Prefix.
Or…
Input 03-26 to program the Country Code.
Or…
Input 03-27 to program the Long Distance Prefix.
Or…
Input 03-28 to program the Local Area Code Tables.
Press [
save
savesave
save]. This advances to the selected database item.
Press [show
showshow
show] to view the contents of this database item.
Press [chg
chgchg
chg] (change) the contents of this database item.
Input the actual code required for the selected function. (For example, “011” for international code.)
Press [
save
savesave
save].
Press the Volume button (up or down) to return to the DB Item Select screen. Or… use the [back
backback
back] or
[
next
nextnext
next] button to skip to the appropriate database item.
Local Area Code programming:
Local Area Code Programming requires two entries; first the local area code, then the code required (usually
the same code) as a prefix when this telephone number is dialed from CID memory.
Press
the Volume button (up or down) to return to the DB Item Select screen.
Enter 03-28 then press [save
savesave
save].
Press [show
showshow
show], Area Code table 1 displays.
Press [chg
chgchg
chg] to change the contents of this database item.
Input the actual local area code that will be received with CID from the local calling area.
Press [
save
savesave
save].
Press [
next
nextnext
next], This area code prefix displays.
If the area code must be dialed to complete local calls within that area code, press [chg
chgchg
chg].
Enter the prefix code here (usually the same digits as the area code) so that local calls dialed from
redial/callback operations to telephone numbers received via CID include this code.
Note: The Area Prefix may be left empty (Null) for callbacks to a local area code – that do not require the
area code to be dialed.
Press [save
savesave
save].
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu.