Specifications

DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-52
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu.
Program the appropriate extension for the Predetermined Call Forward modes required:
Use
¢£¤¥ to highlight “Extension.” Then press «.
Use ¢£¤¥ to highlight “Predetermined FWD.” Then press «.
Use
¢£¤¥ to highlight “Wrong # Dest.,” “Predef FWD Busy Dest.,” or “Predef FWD NoAns Dest.” for
the appropriate extension (extensions are listed along the left side of the screen under the column “DIR#).
Press
« select this database item for change.
Input the destination directory number (extension or UCD/Hunt Group) then press
«.
Note: Frequently the destination for a predefined forward – no answer condition will be to the VM
UCD/Hunt Group, that directory number is 433.
When you have completed all changes, press the
° (escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Press N” to abort changes and leave all data unchanged.
Press Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?
Press N” to abort changes and leave all data unchanged.
Press Y” (yes) to continue with the save operation.
Press
° (escape) again to return to the Database Programming menu.
Program the Predefined Forward Time as required:
Use ¢£¤¥ to highlight “Call Handling.” Then press «.
Use ¢£¤¥ to highlight “Category 3.” Then press «.
Use
¢£¤¥ to highlight “Predefined Forward Time.”
Press « until the desire time displays.
When you have completed all changes, press the
° (escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Press N” to abort changes and leave all data unchanged.
Press Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?
Press N” to abort changes and leave all data unchanged.
Press Y” (yes) to continue with the save operation.
Press
° (escape) again to return to the Database Programming menu.
Continue making other programming changes or exit PC-DBA programming.