Specifications
Maintenance and Trouble Shooting
84 Comdial October, ‘03
3.6.1 CONFIGURATION
1. When you select Configuration, the DX-80 processor sends the current hardware configuration
to PC-DBA for viewing. For each board viewed, the board type is displayed so that the hard
-
ware can be readily identified.
The Option board can be any of the following board types.
Board status can be any of the following.
AAM Automated Attendant Module
8 VOICE
MAIL
BOARD
7271C Flash Voice Mail (with Automated
Attendant), or
7270C Hard Drive Voice Mail (with
Automated Attendant)
Fail/Failed This board is reporting some failure
as a result of the last diagnostic test.
Also, this can indicate that CO lines
are not connected to a CO port or that
Loop Current is no longer present on
the CO lines connected.
Open The board position is Open (not
occupied, and likely never occupied).
Connect This board is reporting connected
(installed and normal) status.
Disconnect This board has been installed and is
now removed.
Block/
Unblocked
This board/port is Blocked/
Unblocked as part of a Maintenance
service function.