Specifications

2.1 Mounting Considerations
The following requirements will help you to install the digital telephone system.
Locate the equipment cabinet within four feet of an AC electrical outlet dedicated
exclusively to the use of this equipment. The outlet must be a 117 VAC 15 AMP circuit
with a third-wire ground supplied to a standard electrical outlet (NEMA 5–15R).
Mount the common equipment within 25 feet of the TELCO/PBX jacks. The recommended
nominal distance is 7 feet.
Choose a secure and dry mounting location that has adequate ventilation. The temperature
range of the location must be within 32-122 degrees F (0-50 degrees C) and that the relative
humidity is less than 90 percent, non-condensing.
If the mounting surface is damp or if it is made of concrete or masonry material, you must
attach a backboard to the mounting surface for mounting the common equipment. Suitable
mounting backboards are available commercially or you can construct one from 3/4-inch
plywood by cutting it to size.
Digital Telephone System IMI66–107
2 – 4 Installing The DSU