SPERIAN SURVIVAIR Opti-Fit™ S-Series Full Facepiece Air Purifying Respirator Operation and Maintenance Manual WARNING DO NOT USE this respirator until you completely read and understand this instruction manual. You are required to inspect the respirator prior to putting it into field service. Please refer to the inspection procedures in this manual. Failure to comply with this warning may result in personal injury, illness, or death.
Table of Contents NIOSH CAUTIONS AND LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . 3 I. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 II. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 III. DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 IV. PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V.
NIOSH APPROVAL CAUTIONS AND LIMITIONS A - Not for use in atmospheres containing less than 19.5 percent oxygen. B - Not for use in atmospheres immediately dangerous to life or health. C - Do not exceed maximum use concentrations established by regulartory standards. H - Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough occurs. J - Failure to properly use and maintain this product could result in injury or death.
NOTE Maintenance or operating procedures and techniques or information considered important enough to emphasize. III. DESCRIPTION The SURVIVAIR Opti-Fit air purifying respirator consists of a full facepiece made of pliable silicone rubber with two connectors for attaching particulate filters, gas and vapor cartridges, and cartridge/filter combinations as required for specific contaminant protection.
WARNING—Continued • Do not use this respirator at ambient temperatures above 130°F (55°C). • Do not use this respirator where environmental conditions could cause the respirator facepiece to be dislodged or slip. • Immediately return to a non-contaminated area if: a. You taste or smell contaminants, or if your eyes, nose, or throat become irritated. b. Breathing becomes difficult. c. The air you are breathing becomes uncomfortably warm. d. You feel nauseous or dizzy. e. The facepiece moves, slips, or leaks.
WARNING—Continued sensitizers. Use positive pressure supplied air respirators to provide better protection from these chemicals. Do not use this respirator if you have been sensitized from previous exposure or believe that you may be sensitive or allergic to any chemical (e.g., isocyanates, latex, etc.) until you obtain clearance from a medical doctor.
IV. PARTS LIST (See Figure 1) ITEM QTY P/N DESCRIPTION 1a 1 702009 Headstrap, TPE 1b 1 702089 Headnet, Mesh, Opti-Fit 2 1 962157 Small Skirt, Silicone 1 962167 Medium Skirt, Silicone 1 962177 Large Skirt, Silicone 3 1 702007 Lens 4 1 962031 Upper Rim 5 1 962037 Lower Rim 6 2 839102 Screw 7 Pkg. of 6 B140001 Inhalation Valve 8a Pkg. of 2 702036 Connector, Bayonet (Incl. 2 Twin Seals) 8b Pkg. of 2 702035 Connector, Threaded (Incl. 2 Twin Seals) 9 Pkg.
Note: Quantities in parentheses are for headnet configuration only. Optional Accessories 702019 Peel-away Lens Cover, Tinted (25) 702028 Peel-away Lens Cover, Clear (25) 962260 Spectacles Kit 951015 1 oz. Lens Anti-Fog Solution 951016 16 oz. Lens Anti-Fog Solution 981803 Wipe, Anti-Fog (Box of 100) 702031 702030 Neckstrap Kit 702031 Neckstrap Kit 702090 Headnet Kit Headstrap Kit, Black Silicone Figure 1. Opti-Fit APRwith withHeadstrap Headstrap (S-Series Version) Figure 1.
Figure 2. Opti-Fit APR with Headnet Figure 2. Opti-Fit APR with Headnet Table 1. Cartridges and Filters (S-Series) Table Cartridges (Threaded Style) (See1.
51 Combination Organic Vapors and P100 1052 Combination Acid Gases and P100 1053 Combination Organic Vapors, Acid Gases, and P100 1054 Combination Ammonia, Methylamine, and P100 1056 Combination Mercury Vapor, Chlorine, and P100 1058 Combination Multi-contaminant and P100 Table 2.
Acroline Carbonyls Hydrogen Selenide Ozone Aniline Cyanogen Methanol Arsine Dimethylaniline Boron Hydrides Dimethyl Sulfate Methylene Chloride, Methyl Bromide, Methyl Chloride Phosphorous Trichloride Bromine Ethyl Cyanide Fluorine Carbon Monoxide Hydrogen Cyanide Nitro Compounds: Nitrogen OxidesNitroglycerinNitrobenzeneNitromethane Stibine Carbon Dioxide Phosgene Phosphine Sulfur Chloride Vinyl Chloride V. HOW TO INSTALL CHEMICAL CARTRIDGES AND PARTICULATE FILTERS A.
WARNING Filters improperly used or improperly assembled to the facepiece could cause leakage, which could lead to personal injury, illness, or death. C. Cartridge/Filter Installation 1. Ensure that you have the correct cartridge and/or filter type for the contaminants in your work area. If you are not sure, consult your supervisor or safety professional. 2.
NOTE When properly adjusted, the headstrap hub should be centered on the back of your head, and the lower straps should be below your ears. OPTI-FIT FACEPIECE WITH HEADNET 1. Inspect the respirator as described in Section XII. 2. Fully loosen all straps. 3. Place your chin against the chin cup and center the facepiece on your face. 4. Hold the facepiece against your face,and pull the headnet over your head. 5.
VIII. HOW TO USE THE RESPIRATOR To receive the maximum protection available from your respirator, you must read, understand, and follow all the Warnings, limitations, and instructions contained in this manual and follow your employer’s instructions on the use and maintenance of the respirator. Read and understand the following warnings prior to using the respirator. WARNING • Never remove the respirator for any reason while you are in the work area.
replaced whenever they are damaged, soiled, contaminated with water, or as soon as they are too difficult to breathe through. Sperian recommends, due to considerations of hygiene, that all filters be replaced at least daily, and more often if necessary. Filters should also be replaced in accordance with schedules established by regulatory agencies. WARNING Failure to properly assemble filter pads to cartridges or filter holders can cause leakage, which could lead to personal injury, illness, or death.
CAUTION Do not use solvent type cleaners to clean any part of the respirator. NOTE Silicone and rubber parts of the facepiece may be cleaned between washings with SPERIAN Mask Wipes, P/N 140096 or 140082. 1. Make a cleaning solution of warm water and a mild detergent. 2. Remove the cartridges/filters from the facepiece. 3. Immerse the facepiece top first in the solution until the exhalation valve is covered. 4. Agitate the facepiece and gently clean with a soft brush. 5.
WARNING • The failure to comply with this warning may lead to personal injury, illness, or death. XIV. REPAIR (See the Repair Table) Repair by the user is limited to replacement of components listed in this manual and as listed on the NIOSH approval label. Disassembly should be performed only to the extent necessary to replace the components. To protect your warranty and the NIOSH certification of the equipment, all other repairs must be done only by authorized SPERIAN technicians and repair centers.
XVIII. ADDITIONAL INFORMATION If you need assistance or additional information on any SPERIAN product, consult your local distributor or contact: SPERIAN 3001 S. Susan Street Santa Ana, CA 92704 U.S.A. (714) 545-0410 or toll free 888-APR-SCBA (FAX) (714) 850-0299 ALL RETURNED PRODUCTS MUST BE DECONTAMINATED PRIOR TO SHIPMENT. PRODUCTS CONTAMINATED WITH DANGEROUS SUBSTANCES WILL BE REFUSED AND RETURNED FREIGHT COLLECT. XIX.
XX. INSPECTION TABLE IF ANY OF THE DEFECTS LISTED ARE FOUND, HAVE THE RESPIRATOR REPAIRED BEFORE USE. COMPONENT LOOK FOR FACEPIECE LENS 1. Nicks, scratches, or abrasions which could impair visibility. 2. Deep gouges or cracks which could reduce impact resistance. 3. Anti-fog coating in need of replacement. FACEPIECE RIMS 1. Deformed, cracked, or broken. 2. Loose screws. Do not overtighten. FACEPIECE SKIRT 1. Cuts, gouges, or punctures. 2. Tears or nicks in the sealing area. 3.
XXI. REPAIR TABLE COMPONENT INSTRUCTIONS HEADSTRAP REPLACEMENT 1. Remove the old headstrap from the facepiece, noting the routing of the straps. 2. Install new headstrap. TWIN SEAL/CONNECTOR REPLACEMENT 1. To remove, rotate the connector clockwise. Lift the connector hook and rotate the connector counterclockwise, and pull outward. 2. Remove twin seal o-ring from groove in lens. 3. To install, gently separate the o-ring and gasket halves of the new twin seal.
XXI. REPAIR TABLE (Continued) COMPONENT INSTRUCTIONS LENS REPLACEMENT 1. Remove any cartridges and/or filters from the connectors. 2. Use a 5/32 inch Allen wrench to remove the two rim screws. 3. Gently separate the rims from the facepiece. 4. Pull the silicone skirt away from the lens. 5. Remove the nozzle cover as described above. 6. Remove the nozzle as described above. 7. Remove the connectors and twin seals as described above. 8.
www.sperianprotection.