User's Manual
INSTALLATION GUIDE FOR RX78V2F-A-AC
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 12
Electrical
700MHz
800MHz
Frequency Range, Uplink
MHz
799-805
806-816
Frequency Range, Downlink
MHz
769-775
851-861
Share Channels
UL sharing 96C, DL 64C+64C
Total Output Power, Uplink (Typical)
dBm
27
Total Output Power, Downlink
dBm
33
33
Maximum System Gain
dB
90
90
Gain Adjustment Range (1dB step)
dB
80(Input 30dB, Output 20dB, digital ATT 30dB)
Pass Band Ripple, p-p
dB
4
4
Uplink Noise Figure at max gain
dB
7
7
Out-of-Band emission
dBc
FCC Compliance
Spurious
9kHz to 1GHz
dBm
FCC Compliance
FCC Compliance
1GHz to 12.75GHz
dBm
Maximum RF Input Power without Damage
dBm
+10
+10
Maximum RF Input Power without Overdrive
dBm
-10
-10
Input VSWR
<
1.5
1.5
Antenna port Impedance
50
50
Mechanical
Dimensions, H x W x D
mm
330 * 490 * 196 (31.7L)
Weight (without bracket)
Kg
20
Power Supply (different hardware type)
VAC
100-240 / 47-63Hz
Power Consumption (Dual band, UL mute)
W
<100
Enclosure Cooling
Convection
RF Connectors * 2
N-Female
Test Port * 4
SMA (UL, DL, DT-Test, MT-Test)
LED * 10
Alarm/RUN
ALM 1~8
Communication port *2
RJ45 (LAN, OMT)
Reserved knock port for external cable rolling
6 ports
Operating Temperature
o
C
-33 to +55
Operating Humidity
95%
Environmental Class
NEMA 4X
Note: Typical specifications at room temperature