User's Manual

MIRCU User Manual
© Comba Telecom Ltd. All Rights Reserved Page 8 of 24
2
nd
Primary Action If MIRCU Support Impact on 1
st
Primary
Scan Support No Impact
Calibration Support No Impact
Set Tilt Support No Impact
L2 /L7 Restoration Support No Impact
Update Configuration File Support Broken Link
Update Firmware Support Broken Link
Get Information Support No Impact
Set Device Data Support No Impact
Self-test Support No Impact
b) Calibration
MIRCU-S24 does NOT support 2 primaries to perform calibration simultaneously.
When 1
st
primary is calibrating, the 2
nd
primary is able to scan MIRCU, restore L2/L7,
get MIRCU information, set device data and self-testing but NOT able to calibrate, set
tilt, update configuration file and update firmware.
When 1
st
primary is calibrating, if 2
nd
primary send command to MIRCU, the impact
on the 1
st
primary is shown in table below:
2
nd
Primary Action If MIRCU Support Impact on 1
st
Primary
Scan Support No Impact
Calibration Reply “Busy” No Impact
Set Tilt Reply “Busy” No Impact
L2 /L7 Restoration Support No Impact
Update Configuration File Reply “Busy” No Impact
Update Firmware Reply “Busy” No Impact
Get Information Support No Impact
Set Device Data Support No Impact
Self-test Support No Impact
c) Set Tilt
MIRCU-S24 does NOT support 2 primaries to set tilt simultaneously. When 1
st
primary is setting tilt, the 2
nd
primary is able to scan MIRCU, restore L2/L7, get
MIRCU information, set device data and self-testing but NOT able to calibrate, set tilt,
update configuration file and update firmware.
When 1
st
primary is setting tilt, if 2
nd
primary send command to MIRCU, the impact on
the 1
st
primary is shown in table below: