User's Manual

MIRCU User Manual
© Comba Telecom Ltd. All Rights Reserved Page 12 of 24
Note 2) 1 primary can operate the command successfully, but the command sent by
another primary failed to achieve.
√:
Note 1) MIRCU-S24 can operate the commands from 2 respective primaries
simultaneously, and comply with AISG standard.
Note 2)When “RESETALD” is run on 2
nd
primary when 1
st
primary is performing an
action, all the action on the 1
st
primary will be suspended.
a) Scan
MIRCU-S24 supports 2 primaries to scan MIRCU simultaneously. When 1
st
primary is
scanning, operation on 2
nd
primary is not affected and it is able to scan, calibrate, set
tilt, reset port, reset ALD, upload/download file, configure MALD and ping.
When 1
st
primary is scanning, if 2
nd
primary send command to MIRCU, the impact on
the 1
st
primary is shown in table below:
2
nd
Primary Action If MIRCU Support Impact on 1
st
Primary
Scan Support No Impact
Calibration Support No Impact
Set Tilt Support No Impact
ResetPort Support No Impact
ResetALD Support Broken Link
Upload File Support No Impact
Download File Support Broken Link
MALD Configure Support No Impact
PING Support No Impact
b) Calibrate
MIRCU-S24 does NOT support 2 primaries to perform calibration simultaneously.
When 1
st
primary is calibrating, the 2
nd
primary is able to scan, reset port, reset ALD
but NOT able to calibrate, set tilt, upload/download file, configure MALD and ping.
When 1
st
primary is calibrating, if 2
nd
primary send command to MIRCU, the impact on
the 1
st
primary is shown in table below:
2
nd
Primary Action If MIRCU Support Impact on 1
st
Primary
Scan Support No Impact
Calibration Return “UseByAnotherPort”
No Impact
Set Tilt Return “UseByAnotherPort
No Impact
ResetPort Support No Impact
ResetALD Support Broken Link
Upload File Return “UseByAnotherPort”
No Impact
Download File Return “UseByAnotherPort”
No Impact
MALD Configure Return “UseByAnotherPort
No Impact
PING Return “UseByAnotherPort
No Impact
c) SetTilt