User's Manual
MIRCU User Manual
© Comba Telecom Ltd. All Rights Reserved Page 10 of 24
h) Set Device Data
MIRCU-S24 supports 2 primaries to set device data simultaneously. When 1
st
primary
is setting device data, the 2
nd
primary is able to scan, calibrate, set tilt, restore L2/L7,
update configuration file, update firmware, get MIRCU information, set device data
and self-test.
**Note: The data that can be changed include Installation date, Installer's ID, Base
station ID, Sector ID, Antenna bearing (degrees), Installed mechanical tilt (degrees)
and Antenna serial number. Antenna model number, Antenna operating band(s),
Beamwidth, Gain (dB), Maximum tilt (degrees) and Minimum tilt (degrees) can NOT be
changed, MIRCU-S24 will reply “Ready Only”.
When 1
st
primary is setting device data, if 2
nd
primary send command to MIRCU, the
impact on the 1
st
primary is shown in table below:
2
nd
Primary Action If MIRCU Support Impact on 1
st
Primary
Scan Support No Impact
Calibration Support No Impact
Set Tilt Support No Impact
L2 /L7 Restoration Support No Impact
Update Configuration File Support Broken Link
Update Firmware Support Broken Link
Get Information Support No Impact
Set Device Data Support No Impact
Self-test Support No Impact
i) Self-test
MIRCU-S24 supports 2 primaries to perform self-testing simultaneously. When 1
st
primary is performing self-testing, the 2
nd
primary is able to scan, calibrate, set tilt,
restore L2/L7, update configuration file, update firmware, get MIRCU information, set
device data and self-test.
When 1
st
primary is performing self-testing, if 2
nd
primary send command to MIRCU,
the impact on the 1
st
primary is shown in table below: