User's Manual

Page 9 of 25
b) Calibration
IRCU-Cx14 do not support 2 BTS to do calibration simultaneously. If one AISG port is
calibrating, the another AISG port is available to scan, L2/7 restoration, get IRCU
information, set device data but set tilt, upload configuration file and update firmware.
When A BTS is calibrating, if B BTS send order to IRCU, the conflict between BTS A&B is
shown in table 7.
B BTS operation
If IRCU Support
Influence on A BTS
Scan
Support
No effort
Calibration
Reply “busy”
No effort
Set Tilt
Reply “busy”
No effort
L2 /L7 Restoration
Support
No effort
Upload Configuration File
Maybe broken link
Maybe broken link
Update Firmware
Maybe broken link
Maybe broken link
Achieve Information
Support
No effort
Set Device Data
Support
No effort
Table 7
c) Set Tilt
IRCU-Cx14 do not support 2 BTS to do set tilt on a band simultaneously. If one AISG port is
setting tilt, the another AISG port is available to scan, L2/7 restoration, get IRCU
information, set device data but calibration, upload configuration file and update
firmware.
When A BTS is setting tilt, if B BTS send order to IRCU, the conflict between BTS A&B is
shown in table 8.
B BTS operation
If IRCU Support
Influence on A BTS
Scan
Support
/
Calibration
Reply “busy”
No effort
Set Tilt
Reply “busy”
No effort
L2 /L7 Restoration
Support
No effort
Upload Configuration File
Maybe broken link
Maybe broken link
Update Firmware
Maybe broken link
Maybe broken link or reply
“WorkingSoftwareMissing”
Achieve Information
Support
No effort
Set Device Data
Support
No effort
Table 8
d) L2 /L7 Restoration
IRCU-Cx14 support 2 BTS to restore L2 or L7 simultaneously. If one AISG port is restoring L2
or L7, do not suggest the another AISG port to do any operation as when the restoration
finish, IRCU will be reset.