User's Manual

Page 8 of 25
NOTICE:
2 BTS concurrent operation IRCU-Cx14 does not support 2 BTS scan, calibration, set tilt, update
configuration file, update firmware simultaneously. Table 5 is the conflict outline for 2 BTS
operation simultaneously.
BTS1/BTS2
Scan
Calibration
Set Tilt
L2
Restoration
L7
Restoration
Upload
Config file
Firmware
Update
Informatio
n
Set
Device
Data
Scan
X
X
X
Calibration
X
X
X
X
Set Tilt
X
X
X
X
L2
Restoration
X
X
L7
Restoration
X
X
Upload
Config file
X
X
X
X
X
X
X
X
X
Firmware
Update
X
X
X
X
X
X
X
X
X
Information
X
X
Set Device
Data
X
X
X
not support 2 BTS concurrent operation
√:
support 2 BTS concurrent operation
Table 5 2 BTS operation simultaneously notice
a) Scan
IRCU-Cx14 do not support 2 BTS scan IRCU simultaneously. If one AISG port is scanning, the
another AISG port is available to calibration, set tilt, L2/7 restoration, get IRCU information,
set device data but upload configuration file and update firmware.
When A BTS is scanning, if B BTS send order to IRCU, the impact to A BTS is shown in table 6
B BTS operation
If IRCU Support
Influence on A BTS
Scan
Support, but if A BTS has
configured bands, then the
bands can’t see in B BTS
if B BTS has configured
bands, then the bands
can’t see in A BTS
Calibration
Support
No effort
Set Tilt
Support
No effort
L2 /L7 Restoration
Support
No effort
Upload Configuration File
Support
Maybe broken link
Update Firmware
Support
Maybe broken link
Achieve Information
Support
No effort
Set Device Data
Support
No effort
Table 6