5.2.6 [DEVICE PARAMETERS]
Figure 9: Device Info
Frequency: set the pilot signal frequency from 902-928MHz, default is 910MHz, user can change the
frequency if there is interferences from 900MHz
OutputPower: Set the output power in dBm for the pilot signal, default is 30 (dBm)
PowerAmplifier: Manually turn on or off the power amplifier
Query Cycle: Set the pulse rate for the pilot signal, minimum pulse rate is 3 minutes
Auto Query: Turn on or off the auto Query