ENU:1-0-0 Copyright Comba Telecom Ltd., March 2009. All rights reserved Page2-16
2.3 POWER SUPPLY REQUIREMENT
The power cable selection should rely on the distance between rectifier and Backplane. At the
power terminal of Backplane for MCPA and Cooling Fans, a 27+/-1Vdc is needed.
CAUTION
z The AC or DC power source must be connected to dedicated lightning
arrestor to avoid damage to TBS system in case of lightning.
z All modules of TBS system should be well grounded.
Normally each MCPA needs 35amps (maximal). The voltage and current requirement for each
power terminal (refer to section 2.3.6.6) is as following table:
Table 2: Voltage and Current Requirement
Power Terminal
at Backplane
DC Input
Power (Vdc)
Maximal
Current (A)
Remark
MCPA 1 26-28Vdc 41 6amps (maximal) for System Controller,
Passive Module and cooling fans.
MCPA 2 26-28Vdc 35
MCPA 3 26-28Vdc 35
MCPA 4 26-28Vdc 35
2.3.1 TEMPERATURE AND HUMIDITY REQUIREMENT
MCPA TBS system can operate at -5 to +50 degrees Celsius and 5%-95% relative humidity
ambient. The HVAC requirement is as following:
Table 3: Total HVAC Requirement for MCPA TBS
Subrack
Quantity
MCPA
Quantity
Total HVAC Requirement For Subrack
Assembly and MCPA Module (BTU/hr)
1 3,915
2 7,194
3 10,474
1
4 13753
5 17,669
6 20,948
7 24,228
2
8 27,508
9 31,422
10 34,702
11 37,981
3
12 41,261