Figure 73: Commissioning Procedure – MU Calibration
Figure 74: Commissioning Procedure – MU Calibration Finish
NOTE1: Calibration is to adjust MU and RU gain to assure system gain is satisfied with the rated gain
(20dB for low power system and 27dB for medium power system), if the band have been calibrated, users
can click to skip the process; if the band never been calibrated, users click in the step of
MU Calibration and RU Calibration, software can still procede to the next step of MU and RU setup, but
the system gain will be a little deviation with the rated gain, so the final output power will be not same with
the target DL output power.
NOTE2: If there are more than one same band access to MU, then each access need to be calibrated in
MU Calibration step, while in RU Cablibration step, users only need to calibrate the band one time,
because all the same band shares the same PA.
Step 5: Click to enter to RU Calibratiion page, refer to step 4 to finish RU calibration.
NOTE1: Make sure the ANT port of RU is connected with dummy load or antennas before Calibration.
Several RU can be calibrated simultaneously.
NOTE2: You can calibrate one RU or calibrate all the RUs at one time. Click “site” in RU table to select all
RUs.