Figure 45: RU Device
NOTE: There are three statuses for PA Service: Normal, Recovery and Shutdown. If PA output power
or reflected power exceeds the threshold (32dBm for LRU, 39dBm for MRU), software will trigger
Recovery:
It will reset PA and then re-detect the PA output power and reflected power, if they are normal, the PA
Service Status will turn to Normal, if PA output power or reflected power is still over the threshold, PA
Service Status will turn to Recovery again.
If PA output power or reflected power is still over the threshold after six times of PA Recovery, PA
Service status will be Shutdown which will need to be reset manually. Reset at Management > PA
Reset.
Click on a specific band on the left side of RU Device page, the corresponding band information will show.
Figure 46: RU Device 700
Band information table
RU common
information table
Select band
to check
relative band
information
This part shows
RU basic
information
Select
700MHz band
700MHz RF
parameter setting
table
700MHz alarm
information and
configuration table