Datasheet

CARATTERISTICHE ELETTRICHE E
MECCANICHE
Electrical & Mechanical Specifications
CODICE – CODE:
CE0336
FOGLIO - SHEET:
7 of 10
MECCANISMI DI PROTEZIONE Protection Mechanisms
Tamb=25°C; fin=50Hz, se non specificato altrimenti Tamb=25°C; fin=50Hz, unless otherwise specified
PARAMETRO
Parameter
CONDIZIONI
Conditions
MIN TYP MAX UNITA'
Unit
1 Input Under-Voltage Full load 70 Vrms
2 Input Over-Current By fuse T 0.8 Arms
3 Input Inrush Current See page 3
4 Output Short-circuit Vin = 100Vrms – 60Hz
Vin = 240Vrms - 50Hz
1.40
1.35
A
A
5 Output Current Limiting
(Vth = 11.64Vdc)
Vin = 100Vrms – 60Hz
Vin = 240Vrms - 50Hz
1.25
1.25
A
A
6 Over-Current Protection Vin = 100-240 Vrms LEAN-FORWARD MODE
(*)
7 OV and open-loop Vin = 100-240 Vrms; full load BURST MODE
8 Output Under-Voltage
9 High Temperature 135 142 150 °C
10 Reset Time
Note 1: The device shall shutdown without latch-off if the input voltage goes down the specified limit. This value is measured at full load.
Note 2: The device has an internal over-current protection. A slow-blow, high breaking capacity fuse (not accessible) is placed in the line side of the input
circuit.
Note 3: The device has an internal inrush current protection. A NTC resistor (not accessible) is placed in the line side of the input circuit.
Note 4: The device shall not be damaged when input power is applied with a short-circuit (about 0.01 ohm) from the output voltage to its return. During
this condition the device produces a constant output current.
Note 5: Maximum steady-state output current obtainable from the regulated output (Vth = Vrated – 3% = 11.64Vdc).
Note6: The device shall not be damaged when input power is applied with an output over-load. During this condition the device produces a “LEAN-
FORWARD MODE” working.
Note 7: When the output voltage exceeds specified value the device shall shutdown without latch-off and goes in the burst mode operation. During burst
mode the output voltage pulses with peak value of about 17V.
Note 8: When the output voltage goes down specified value the device shall shutdown without latch-off the output.
Note 9: When the junction temperature reaches specified value the controller ic shall shutdown and protects other components from failure. The
temperature protection is not-latching; after an over-temperature shutdown, the controller will restart as temperature drops.
Note 10: If the device latches-off due to a fault condition, it shall return to normal operation only after the fault has been removed and the supply is reset.
Duration of the off-time necessary to reset the device must be at least as shown.
(*) LEAN-FORWARD MODE
The equipment permits the current to be increased by a factor 1.4 of the maximum rated value, and
slowly reduces the output voltage (up to the full short-circuit). The short-circuit current can be supplied
indefinitely, without damage the power supply.
All parts included in this documentation are property of
COMATEC snc. All rights reserved. This document and
its information (or part of its) can't be reproduced or used
without an explicit written permission.
PSM 1 12 12
DATA DATE:
11-11-2010
EDIZIONE – ISSUE:
2
nd
Ed. Rev.A