Operating Instructions and Installation Instructions

CSB200 Class B AIS
R2.0 33
TROUBLESHOOTING GUIDE
Problem Possible cause Solution
General
CSB200 is not
detected on proAIS
The AIS is not
connected to the
serial port selected
from the drop down
menu.
The AIS is not
powered.
The serial cable is
damaged or faulty.
Check the number of
the serial port the AIS is
connected to and retry.
Check that the power
supply is connected
and switched on.
Try an alternative serial
cable.
Static Data tab
No static data is
displayed
The unit has not yet
been configured
Follow instructions in
the Static data section
to configure the unit
The MMSI can not
be changed
The MMSI has
already been
programmed
The MMSI can only be
programmed once. If it
is incorrect please
contact your dealer.
The static data is
incorrect
Data was entered
incorrectly
Re-enter the static data
and save to the AIS.
The MMSI cannot be
updated.
GPS tab
No GPS position
information is
displayed
(or graph shows only
blue bars)
The unit has not
acquired GPS fix
Check the GPS
antenna connections
and power cycle the
AIS unit.
CSB200 Class B AIS
R2.0 34
Problem Possible cause Solution
The GPS antenna is
not correctly
connected
The GPS antenna
does not have a clear
view of the sky
GPS antenna is
unsuitable for use with
AIS
Check the GPS
antenna location and
make sure it's view of
the sky is not
obstructed
Check the AIS
installation manual
against the specification
of your GPS antenna
Diagnostics tab
Red cross against a
status item
Unit configuration or
antenna connections
See Diagnostics tab
section of this user
guide for advice on
each item
Active alarm shown:
Position sensor fault
OR
SOG data fault
OR
COG data fault
The unit has not
acquired GPS fix
Wait at least five
minutes for the unit to
acquire GPS position fix
Follow troubleshooting
guide for GPS tab
Active alarm shown:
VHF Antenna VSWR
fault
The VHF antenna is
not connected or is
not suitable for use
with the AIS
Check the VHF antenna
connections.
Check the AIS
installation manual
against the specification
of your VHF antenna
Active alarm shown:
12V Power supply
fault
The power supply to
the AIS is outside the
specified range.
Check the power supply
voltage to the AIS
against that specified in
the installation manual.