Operating Instructions and Installation Instructions
CSB200 Class B AIS
R2.0 31
LED Status Indicators
Power Status Timeout Error TX
Off
TX RX Indicates
9 9
Blinking Blinking Normal
9
9 9
Fixed No MMSI
9
9
Blinking No GPS
9
9
9
Blinking Tx off Switch
9 9
9
Blinking SRM switch
The table above is a quick reference check on the operational status of
the CSB200, for more detailed information it is recommended to view the
Diagnostics page in the proAIS program.
Built in Integrity Test
The CSB200 is equipped with Built In Integrity Testing (BIIT). BIIT tests
run continuously or at appropriate intervals simultaneously with the
standard functions of the equipment. The BIIT detects any failure or
malfunction that will significantly reduce integrity or stop operation of the
CSB200 unit.
The tests include:
• AIS TX malfunction (synthesiser not locked and TX time-out not
exceeded)
• Antenna VSWR exceeds limit
CSB200 Class B AIS
R2.0 32
• Rx channel 1 malfunction (synthesiser not locked)
• Rx channel 2 malfunction (synthesiser not locked)
• Internal GNSS not in use
• No valid SOG information
• No valid COG information
• Background noise > -77dBm
• GPS failure
• VSWR exceeding the maximum allowed level
• The input voltage is out of the specified range
MAINTENANCE
WARNING: Unauthorized opening of the CSB200 unit will invalidate the
warranty.
CAUTION: Avoid using chemical solvents to clean the CBS200, solvents
may damage the case material.
NOTE: The CSB200 contains no serviceable parts. Contact your local
Dealer if the unit fails to function correctly.
www.Busse-Yachtshop.de email: info@busse-yachtshop.de