Specifications
Error Messages
Table A–2 describes possible EtherWORKS 3 Turbo board error
messages and the recommended corrective actions for each group of
messages.
Table A–2 Error Messages
Message Recommended Actions
Unable to determine I/O address
Ethernet Address ROM CRC failed
Wrong Card ID
Register R/W test failed
EEPROM Checksum test failed
Ensure network configuration file
settings (PROTOCOL.INI for NDIS
users, NET.CFG for ODI users) match
the settings of the Turbo board.
Ensure there is no I/O conflict (that
occurs when two boards live in the
same I/O space). Try to hardstrap the
board and use NICSETUP to program
the board to live in another I/O space.
Refer to the README file for details
about how to hardstrap the board.
Refer to the Turbo board distribution
diskette file A:\Error.txt for more
information and troubleshooting
tips regarding the diagnostic error
message.
If neither corrective action works, you
may have a defective board. Contact
your Digital Sales Representative.
(continued on next page)
A–6