Colzer Dehumidifier User Manual Model No.: TR160D Please read this User Manual before operating and keep safe for future reference.
Welcome Thanks for your purchase and welcome to the Colzer family. We suggest that you read this user manual before plugging in your new dehumidifier as it contains important safety information, operation instructions, troubleshooting, maintenance tips, and warranty information to ensure the reliability and longevity of your dehumidifier. We also kindly ask you to take a few minutes to register your product at colzersmart.com/vip for more efficient support as well as updates, promos, and other cool stuff.
CONTENTS Safety Information.................................................................................1 Product Specifications...........................................................................2 Features.................................................................................................2 Parts Identification................................................................................3 Operation Instructions........................................................................
SAFETY INFORMATION • Install the dehumidifier on flat surface to minimize vibration and or noise. • Inspect the power cord before use. Never operate the dehumidifier when the power cord or plug is damaged. • Insert the three-prong plug on the power cord into a matching electrically grounded outlet (115V/ 60 Hz, 15 A at least). Do not use an adapter. Never cut off the third prong. Do not use an extension cord. • Do not operate the dehumidifier in standing water. Keep motor and wiring dry.
PRODUCT SPECIFICATIONS Colzer Dehumidifier Model No. TR160D Power Source AC 110-120V, 60 Hz (80°F, RH 60%) (86°F, RH 80%) Input Power 735 W Input Current 7.0 A Moisture Removal 93 Pints/Day Input Power 835 W Input Current 8.0 A Moisture Removal 160 Pints/Day BCSC 15 A Motor Compressor RLA:7.3A; LRA:36.4A Refrigerant R410a (18 oz.) High Pressure 522 PSIG (3.6 MPa) Low Pressure 240 PSIG (1.65 MPa) MADE IN CHINA CONFORMS TO UL STD. 60335-1&60335-2-40 CERTIFIED TO CSA STD. C22.2 NO.
PARTS IDENTIFICATION Integrated Handle (Foldable) Colzer Info Air-inlet Grille Wheel Remove to Access Pump Control Panel Air Outlet Wire Nail Handle Latch Power Cord Winder Drain Hose Label Area NOTE: DO NOT OBSTRUCT THE AIR INLET OR OUTLET.
OPERATION INSTRUACTIONS 1. Install the Handle 1) Remove the handle from the buckle and flip the handle up 180° to align the hole position of the handle and the handle holder; 2) Insert the corded bolts into the holes of the handle holder and the handle by pressing and holding the metal button on the top of the bolt. 3) Release your finger when you have inserted the bolt to the latch.
windows that open to efficiency. Place your dehumidifier away from obstructions, and keep it away from anything that could block airflow into and out of the dehumidifier. 3. Set Up the Drainage The dehumidifier pump connects to a plastic drainage hose. The hose, stored on the back of the dehumidifier, is equipped with a quick-connect fitting for easy attachment to the drain outlet.
5. Understand the Control Panel Display Screen - The first line of the display shows the total number of hours the dehumidifier has been in operation. It will also countdown the timer on the right if the timer function has been activated. - The second line of the display shows current temperature and humidity of inlet and outlet. Power Button: Press to turn the dehumidifier ON or OFF. - To Turn the Dehumidifier ON: In standby mode, press the POWER button to turn the dehumidifier on.
Water Full Indicator: When the water pump is full of water, the indicator light turns on to remind the user to drain. Purge Button: Press to empty water from the condensate pump reservoir. Use "PURGE" before moving the dehumidifier to avoid water spillage. During normal operation, the pump purges automatically when the reservoir is full. The FULL indicator will light up after you pressed the PURGE button, which means the pump is working.
Smart Functions Auto Drainage Thanks to the built-in pump, the dehumidifier will drain the condensation water automatically. Wait 3 Minutes before Resuming Operation To avoid any damage to the dehumidifier, the dehumidifier will not start operation following a complete cycle until after 3 minutes. Operation will automatically start after 3 minutes. Auto Defrost When the frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears.
Cleaning the Air Filter The working performance of the dehumidifier will be greatly reduced if the filters become blocked. To Clean the Filter 1) Pull out the air filter from the top side gently. 2) Vacuum any debris from the filter using the vacuum hose and nozzle attachment. 3) Immerse the filter into lukewarm water (about 40°C) with a mild detergent, and then wash it and allow it to dry. 4) Once dry, re-install the filter into the dehumidifier.
TROUBLE SHOOTING GUIDE Problem Dehumidifier does not operate Dehumidifier collects little water dehumidifier operating, but room not dry Possible Cause Solution No power to dehumidifier Connect plug to power socket Switch not turned on Switch on E4 error is displayed Check drainage flow Insufficient working time Allow more working time Filter is blocked Clean filter Low ambient temperature Heat up the room Condensate hose is blocked Check hose for restrictions Doors and windows are open S
Warranty Information Colzer offers a limited 1-year warranty on all of our products, with original proof of purchase and where a defect has arisen, wholly or substantially, as a result of faulty manufacture, parts or workmanship during the warranty period.