Operators Safety & Instruction Manual

ADDITIONAL STRIPPING
Remove the extractor pin [1] using a suitable punch.
Remove the extractor and spring assembly do not separate the spring from
the extractor or the rubber insert from the extractor spring. Ensure that the
“D-ring” is present.
Push the receiver pivot pin [2] all the way to the right.
Separate the upper and lower receivers.
Press in on buffer [3], depress the buffer retainer [4], and release the buffer under control.
Remove the buffer and return spring [5].
Ensure that the elastomeric (black rubber) spring [6] is in place. It may be removed for cleaning.
16