Operating instructions

2.2. Set-up
A special foundation is not required for installation.
The dryer must be installed on a level surface, and may not be exposed to
excessive humidity. Maximum permissible ambient temperature of the control
system is 45° C.
To facilitate servicing, install the dryer such that it is accessible from 3 sides.
Make sure that the air filters can be changed without problems. The rear of the
dryer can be placed against a wall.
»
The main switch must be freely accessible.
To conserve energy, keep the distances between dryer, hopper and processing
machine as short as possible.
2.3. Mounting of the suction device for regeneration exhaust air
When plastics are dried which produce hazardous gases, environmentally sound
disposal of the regeneration exhaust air must be provided. The throughput of the
regeneration blower may not be changed.
It must be taken into consideration when installing a disposal system (e.g.
exhaust system) that regeneration exhaust air is extremely humid. This may
result in condensation water which must not enter the dryer again under any
circumstances.
Dehumidified air dryer
Assembly instructions 2-5