Operating instructions
•
Note that too large amounts taken from the drying hopper lead to insufficient
drying of the material.
•
Close the air stop valves of drying hoppers which are empty or have not been
used.
•
Note down all data which you have entered into the control system.
•
The password is to be entrusted to authorised personnel only.
•
Please note that the temperature of the dryer heating system must always be set
lower than that of the supplementary heaters.
•
When you dispose of drying agents, observe all official rules.
•
Note that drying cells are replaced or refilled by Colortronic only if they are empty.
•
The material level may not fall below 40 % in the drying hopper, when material is
continuously removed from the drying hopper, but no material is continuously fed
into the drying hopper (batch drying). Close the throttle valves.
•
Read the operating manuals of the connected devices.
Dehumidified air dryer
Safety instructions 1-10