Operating instructions

5.1. Maintenance schedule
Daily: Check warning signs on equipment for good
legibility and completeness
Clean return air filters and casing
(depending on dust build-up)
Weekly: Check main switch for proper function
Check the signal lamps for proper function
Every six months: Change return air filters
(depending on dust build-up)
All electrical and mechanical connections
should be checked to see if they fit securely
Annually: Dewpoint should be checked (only by
Colortronic service personnel)
Whenever the
material is changed: The drying hopper and suction box must
be cleaned
&
The service intervals refer to a 3-shift operation.
F
The given maintenance intervals are average values.
Check whether in your individual case the maintenance inter-
vals must be shortened.
64.10-0067GB10 06/00
CTT 30
Maintenance 37