Operating instructions
8.3. Electrical Connection
»
Observe the rules of the local electricity board.
Check that the supply voltage and the power frequency are in accordance
with the data on the name plate of the device.
The electrical connection may only be carried through or assigned by
Colortronic service staff or by qualified staff authorized by Colortronic.
Other persons are not permitted to carry through the electrical connection.
The main switch must be freely accessible.
Ground the equipment against electrostatic charging.
F
Regularly make sure that none of the electrical or screw connections are
loose.
Make sure that the main switch is at “0" position before the electrical con-
nection is carried out.
Standard operating voltage is
CTT40: ...............................................230V/AC/50 Hz (Europe),
.........................................................230V/AC/60 Hz (U.S.).
CTT70: .............................................400V/3AC/50 Hz (Europe),
.......................................................460V/3AC/60 Hz (U.S.).
Special voltages can be supplied on request.
The connected loads* are
CTT40...........................................................max. 1.3 kW,
CTT70 .......................................................... max. 2.0 kW.
*If hopper heaters are installed, the value of each hopper heater must be added to these con
-
nected loads (CTT 40: max. 1.5 kW, CTT 70: max. 3.0 kW).
The fuse protection must have
CTT40 .................................................................16A,
CTT70................................................................. 16A.
64.10-0214GB10 04/02
CTT 40 / CTT 70
Assembly instructions 8-3