Specifications
REFERENCE MANUAL
NSI CORPORATION MC 24/48 Version 1.03
27
-O-
OVERTEMP LED
Location: Indicator, Right Console Face, above [BLACKOUT] Hard key
The red OVERTEMP LED illuminates when a dimmer rack is close to automatically turning itself off due
to an obstructed air flow. This feature only works when the console is connected to a Colortran Dimmer
Rack.
-P-
[PART]
Location: Data keypad
(this key reserved for implementation of future features)
[PATCH]
Location: Display keypad, bottom row
Use the [PATCH] display hard key to change the screen to the Patch display. The Patch display is a used
to assign control channels to dimmers. The Profile, Non-Dim Dimmers, and Parked Dimmers displays are
also available in the Patch display, under their respective soft keys.
A channel may control multiple dimmers. Any dimmer may be given a proportional level. If a dimmer has
previously been assigned to a channel, and it is subsequently patched to another channel, it is robbed from
the previous patch location. To subtract a single dimmer assignment and retain the other assignments for
the currently selected channel, use the [MINUS] key.
In the Patch: By Channel and Patch: By Dimmer formats, the first column lists each dimmer or channel in
numeric order. The second column lists the patch assignment, in numeric order. The third column, Level
%, lists the dimmer level, which is the proportional level for that dimmer. The fourth column, Profile, lists
the profile assigned to the dimmer.
A dimmer may be parked, assigned a custom profile or assigned virtual non-dim status. You can also
select the Profile Editor display from the Patch display.