Service manual

SECTION 5
DISASSEMBLY AND ASSEMBLY
45
4. Remove Top Cover. Remove mounting screw on
left-hand side (Control Panel Side). Remove Top
Cover and set aside.
5. Remove Antistatic Brush Assembly [A] from
mounting studs. Unlatch the two latches (one on
either side of the Assembly) and lift the Assembly off
the four mounting pins as shown. Do not bend the
brushes!
CAUTION
DO NOT BEND, PINCH OR CUT THE INK
LINES LOCATED DIRECTLY IN FRONT
OF THE BRUSH ASSEMBLY.
NOTE: Make sure Brush Assembly is correctly reinstalled
and aligned before starting to print. Assembly should sit
flat on transport area surface.
6. Unplug the Network, USB and Main
Power connectors from Print Engine
Circuit Board.