Technical data

9
L1
L2
L3
L5
L4
570
571.1
571.2
Part II – Explanation of Controls
A) Electronic Touch Pad – (Refer to figure 4)
Figure 4
This machine is equipped with one electronic touch
control pads. This electronic touch pad operates all
controls of the freezer.
Indicator Lights – L1 through L4
These indicators illuminate to show the selected machine
function. When illuminated, the machine is in that
respective mode.
Indicator Light – L5
This light will illuminate when the mix tank is low or out
of mix. It is also possible to activate a low mix level
beeper in the programming mode.
Monitor – Position 570
This numerical monitor will display the cylinder product
consistency while the machine is freezing product in the
automatic mode. When not freezing the product in the
cylinder, it will display mix tank temperature in ALL
modes.
Stop / Reset – Position 571.1
When in this mode, the indicator light L1 will be lit and
the machine functions off. From this mode you can
access the programming mode or switch to operating
modes.
Push to Select – Position 571.2
By pressing this button you can select any of the
following machine modes:
- Automatic
- Stand-by
- Beater
The indicator light will illuminate corresponding to
the mode selected with the touch pad.
Automatic Mode
When placed in this mode the indicator light L2 will
illuminate and the machine will start the freezing
process in the cylinder. During this freezing process,
a number indicating the cylinder consistency will be
displayed (monitor #570, the lower the number,
softer the product). The machine will continue to
freeze the product in the cylinder (numbers will
increase) until the preset HOT number value is
achieved. After achieving the preset cylinder
consistency number (HOT) the machine will then
start cooling the mix tank and display mix tank tem-
perature.
Stand-By Mode
When placed in this mode the indicator light L3 will
illuminate. This mode is used during prolonged idle
periods. The mix temperature in both cylinder and
mix storage tank is maintained below 40 degrees F
by the electronic temperature probes. Product should
not be served while in this mode as it will be too soft.
The Monitor (#570) will only display the temperatu-
re in the mix tank while in this mode.
NOTE: If the mix level in the tank is below ½ full, a
warmer than actual temperature will be displayed
on the Monitor #570. The actual mix temperature
will remain at a safe temperature below 40 degrees F.
Beater Mode
When placed in this mode the indicator light L4 will
illuminate. This mode is used during the start-up
(pump fed), cleaning and sanitizing of the machine.
While in this mode the ONLY the beater / auger drive
motor will operate. This mode has a built in safety
device which will automatically switch the machine
to the stop mode after 15 minutes of operation. This
safety prevents an operator from inadvertently
leaving the freezer in this mode for extended periods
of time, which could damage the freezer.
Mix Tank Low Level Indicator
When low on mix in the mix storage tank, the
indicator light L5 will illuminate. This will indicate
that more mix is needed to operate the freezer. Each
mix tank has a maximum capacity of 10 quarts each.