D) Disassembling the Beater / Auger
Remove the beater / auger assembly from the cylinder
by pulling straight out of the machine towards you.
Disassemble the beater / auger by first removing the
rear rubber beater shaft seal.
Next disassemble the center idler from the beater /
auger frame. To remove, pull the idler straight out of
the front of the beater / auger.
Finally, remove the beater / auger end pusher by
pulling straight out of the beater / auger frame.
Remove the scraper blades from the beater / auger fra-
me by gently rotating the blade out of the frame
support brackets.
The machine is now completely disassembled. The
removed parts must now be washed, rinsed, and
sanitized.
E) Cleaning Operation
Wash the removed machine parts in luke warm (80-90
F) water and mild non-foaming detergent. Scrub each
of the parts with the cleaning brushes provided in the
machines spare parts kit.
!! IMPORTANT !!
DO NOT use hot water on any of the plastic parts as
this may result in damaging these parts.
Using your three-tank sink, wash rinse, and sanitize all
of the disassembled machine parts. Mix the sanitizing
solution to a 200ppm concentration with warm water.
Allow the parts to soak in the sanitizing solution for 3-
5 minutes before removing. Allow the parts to air-dry
on the clean, sanitized counter at the end of the sink.
DO NOT towel or sponge dry these parts.
3) Sanitize
1) Wash
2) Rinse
4) Air Dry