GENERAL TESTING PROTOCOL
Always test outdoors under optimal sunlight conditions.
A. Test Solar Panels for Voltage.
Connect Voltmeter to each individual panel separately and observe Open Voltage. Open Voltage can range
from 16 Volts to 24 Volts. Once all panels test for voltage, proceed to step B. (Using a solar voltage tester is
also an option)
B. Test Connection to Charge Controller for Voltage.
Reconnect Solar Panels, and connect to charge controller as per instructions. Measure the open circuit
Voltage at the battery side of the charge controller. Open circuit voltage should read 5-10% lower than without
charge controller. Open circuit measurement will read between 15 and 23.5 Volts DC.
C. Connect Charge Controller to Battery.
First, disconnect solar panels and connect charge controller to battery. Always connect charge controller to
battery first and remove last. Observe polarity – positive to positive and negative to negative.
Maintenance Instructions:
Cleaning of the glass may be performed by the user by utilizing a clean, damp cloth.
Any other maintenance to the unit should be performed by qualified service personnel or contact our
experienced customer service team.
WARRANTY
The solar panel is covered by a twenty-five year limited warranty of 80% of power output, and must be tested under optimal
conditions. This product is warranted from defects in materials and workmanship for a period of two years from date of
purchase. This warranty does not apply in the event of misuse or abuse and or repairs and alterations.