Specifications

16
General Operating Specifications
12V 24V
Minimum operating voltage 8.5v 8.5v
Maximum allowable intermittent/surge voltage (1) 45v 45v
Maximum input from solar panels (VOC) 24v 48v
Preferred maximum input from solar panels 18v 36v
Maximum continuous solar charge amperage (2) 60A 60A
Maximum continuous diversion amperage (2) 60A 60A
Maximum surge solar charge amperage 80A 80A
Maximum surge diversion amperage (resistive)
80A 80A
Energy consumed by the electronics (meters off) < .1W < .15W
Energy consumed by the electronics (meters on) 1.2W 1.0W
On state resistance of the mosfets at 77F -- (Ohms) 0.002 0.002
Voltage drop across mosfets during charge at 60 Amps .12V .12V
Minimum float setting (volts) 12.5 25
Maximum float setting (volts) 14.5 29
Factory default float setting (volts) 13.5 27
Minimum bulk setting (volts) 13 26
Maximum bulk setting (volts) 15 30
Factory default bulk setting (volts) 14 28
Time in absorption charge once bulk set point has been reached 1 hour 1 hour
Time in equalize charge once equalize set point has been reached 2 hours 2 hours
(2) -- May require automatic 30 second cool down periods if air flow though the enclosure is not sufficient
For indoor use only. Install in a non-corrosive, dry environment
only.
External dimensions of the enclosure (Inches)
8.5 x 12.5 x 4.5
Minimum ambient air temperature -20F
Maximum ambient air temperature (60 Amps) 72F
Maximum ambient air temperature (40 Amps) 90F
Maximum ambient air temperature (30Amps) 120F
Designed for battery-based systems only.
These specifications and measurements are subject to periodic change without notice.