Installation guide
035-15266-003Rev.A(0804)
2 SPADE 0NSUL )
TERMINALS USED WHEN
CHANGING SPEEDS
BLOWER
RELAY
MODEL: EB17B
,6
NOTE: IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH
THIS UNIT MUST BE REPLACED. IT MUST BE
REPLACED WITH TYPE 105°C THERMOPLASTIC
OR ITS EQUIVALENT. FACTORY WIRING SHOWN
SOLID. FIELD WIRING SHOWN BROKEN.
WIRING MUST CONFORM TO LOCAL CODES
APPROVED FOR CU CONDUCTORS ONLY.
SINGLE BRANCH $
CIRCUIT SERVICE
NOMINAL CIRCUIT LOAD-AMPS
WIRE SIZE (75 ° C) COPPER
WIRE SIZE (60 ° C) COPPER
MAX, FUSE SIZE
(OR CB) - AMPS
DUAL BRANCH
CIRCUIT SERVICE
BRANCH CKT. LOAD-AMPS
BRANCH CKT, MIN, AMPACITY
WIRE SIZE (75 ° C) COPPER
WIRE SIZE (60 ° C) COPPER
MAX, FUSE SIZE
OR CB) - AMPS
SREQUtRES JUMPER BARS (P/N 3500-378/*)
2 LEADS +
1 GROUND
70.7
#3
#2
9O
4 LEADS +
2 GROUNDS
CKT #1 - CKT #2
47.3 23.4
59.2 29.3
#6 #10
#4 #10
60 30
FIGURE 20 : EB17B WIRING DIAGRAM
14 Unitary Products Group