Specifications

38
For additional help contact our Customer Support hotline:
+1-800-777-9101 (+1-513-576-8981)
Problem Check This Solution
Machine will
not start
GREEN light is
not on
Is the unit plugged in? If NO...Plug Unit in.
Is the power switch in the
ON (I) position?
If NO...Push power
switch to I.
It still will not start up? Call Cold Jet for support.
Machine will
not blast
Is the machine active light
(the BLUE light) on?
If NO...
Close the hopper access
door and reset the E-
stop. Also make sure
the slide-out hopper is
latched closed (DX only).
If the above doesn't work
then check fuses FU1
& FU2
Is the applicator safety
switch pushed back?
If YES...Flip the switch
forward.
Is the optional Coalescing
Filter gauge redlining?
If YES...Immediately
replace the filter element.
Is the air supply connected
and the air supply on?
If YES...The nozzle may
be clogged, blast with air
only to unclog it.
Is the air supply gauge
showing pressure?
Is the optional pressure
regulator open and
displaying pressure?
Is applicator cable connected
to the machine and the
applicator?
Machine blasts
AIR but NOT
pellets
Set feeder speed and check
the thumper for movement.
If no movement see
below.
Do Vibrator fuses FU3 and
FU4 glow orange?
If YES...Replace the
fuse(s) that glows
orange.
The Hopper may be clogged.
Squeeze the trigger to
break up ice clumps.
A foreign object may be
lodged in the feeder.
Call Cold Jet for support.
Maintenance
Troubleshooting