Specifications

34
1 Push the Applicator Safety Switch
forward.
2 Purge the system by blasting with air
for 1 min.
How to Purge:
Before loading the pellets into the hopper, turn the feed
control to its maximum setting and pull the trigger.
After purging, return the feed control to the desired
blast setting.
3 Pour the pellets into the hopper.
4 Close the Fill Lid.
5 Squeeze the Applicator trigger to blast.
If desired push the speed switch up to increase the feed
rate to clean tough spots (AeRO 75-DX ONLY).
IMPORTANT
Pressing and releasing
the aPPlicator trigger
makes the thumPer break
uP any ice clumPs.
IMPORTANT
LETTING THE SYSTEM
RUN UNTIL IT EMPTIES
KEEPS THE UNIT IN IDEAL
CONDITION.
Blasting
Operation