Technical data

You are now ready to disassemble and clean your
D)
Proximity Switch
freezer. Please refer to Part
I11
-
Initial Cleaning Pro-
The sensitivity of'this switch can be adjusted
cedure of this operation manual for instructions on
with a small screwdriver. The trimmer location
how to proceed..
is on the switch body nearest the front panel.. To
adjust, the adjustment screw should be turned
!!
IMPORTANT
!!
very carefully either in a clockwise direction to
increase the range or counter clockwise to
-
You
MUST
disassemble the machine after draining
decrease the range of operation
and follow the described cleaning and sanitizing
procedures as described in this operation manual in
order to maintain acceptable hygienic levels in your
product.
Part
IX
-
Technical Information
A)
Refrigeration:
Compressor -Hermetic I Low Temperature
Suction Pressure (Cylinder)
-
18-2 1 psig
(Mix Tank)
-
20-25psig
Discharge Pressures
-
250 to 260psig
Refrigerant Type
-
R-404A ONLY
Cooling Type
-
Air or Water
Cylinder valve type
-
TXV wlequalizer
Mix tank valve type
-
AXV
Refrigerant Charge- See Machine Data Plate
B)
Beater
/
Auger Drive Motors
Motor Type
-
Leeson
-
ODP with C flange
Beater Rotation-(facing front of freezer)-CCW
H.0.T Amps
-
7.6
single phase
Minimum Operating Voltage
-
200vac
Maximum Operating Voltage
-
240vac
C)
Thermal Overload
Overload Setting
-
9.0 single phase
Overload Ranges
-
7..5-
1
1 amps
-
single phase
Thermal Overload
-
Calibrations and Settings
(Top View)
AMP.
CALIBRATION,
ALWAYS IN
R POSITION