Technical data
Part
V
-
Sanitizing the Freezer
Prior to filling the machine with fresh liquid mix, the
assembled machine must be sanitized The frequency
of cleaning and sanitizing must comply with your local
and
/
or state health regulations
If
uncertain of these
regulations, contact your local Health Departments or
Department of Agriculture
With the dispensing handle closed, pour an even
amount of the sanitizer solution into the mix tank
With the large cleaning brush, clean all surfaces of the
mix storage tank with the sanitizing solution
Sanitizing your freezer is very important. This proce-
dure will retard the growth of bacter ia and insure
excellent product bacter ia test results performed by
your local inspectors
To begin, you will need the sanitizer, spatula, large
cleaning brush, (all included in the start up kit), and
clean pail.
With the cylinder full
ofthe sanitizer solution, push the
"Push to Select" button on the fr.ont touch pad (#5712)
until the beater mode is selected.. Allow the machine to
run in the beater mode for approximately 30 seconds.
Mix the sanitizer
(Stera Sheen green label or
equivalent) into the clean pail with at least two gallons
of warm water. Mix the sanitizer and water to make a
200-PPM. concentration of'sanitizer solution.. Using
the spatula, stir the solution until the sanitizer is
completely dissolved.
!!
IMPORTANT
!!
Do not exceed the formula recommended by the
sanitizer manufacturer as it will not add to the
sanitizing effectiveness. DO NOT use straight
chlorine bleach since it does not clean properly and
will damage plastic components. Do not
leave the
sanitizing solution in the freezer longer than one
hour as it can corrode some parts.
!!
IMPORTANT
!!
Do not select the "Automatic" or "Stand-By
"
modes
while sanitizer is in the machine as this can possibly
damage ,your, freezer. Select only the "Beater "mode
while cleaning or sanitizing the, freezer.
PUSH
TO
571.2
SELECT
Press the "Stop
-
Reset" button (#571..
1)
and place the
machine in the
OFF
/
Stop mode. Allow the sanitizer to
remain in contact with all of the product surfaces for
3
to 5 minutes.
@
STOP
RESET
El-