Technical data
Once the orings have been installed onto the piston,
place a bead of lubricant between the orings
&;m
Spread the lusicant to lightl, coat the piston surface
between and including the orings This will ensure fiee
movement ofthe pistons and dispensing handles.
Turn over the dispensing head and insert the two large
orings into the grooves in the dispensing head.
Lightly
lubricate the outside of these or ings.
Insert the piston into the center chamber of the
dispensing head The center piston is identified with
the one piece
"H
type or ing
When installing, align the square handle recess with
the rectangular cut out of the head
Repeat this process with both end pistons
Install the dispensing handles onto the head by placing
the rounded side of the metal cam into the piston notch
Insert the metal retaining rod into the dispensing head
and piston cams When the handles is installed, affix
the small oring into the metal retaining rods oring
groove