User`s guide

STANDARD PRINTER COMMANDS
52 Copyright © 2006, Cognitive.
previous label. (See also
AREA_CLEAR command.)
!A
Automatic header line.
Same as !, except
remaining header line
parameters are not
required. The printer sets x
to zero, dottime to 100,
calculates MaxY, and sets
numlbls to zero. MaxY is
calculated based on the
location of the last plotted
row in the image buffer. Use
this header line with the
QUANTITY command or in
stored label formats. This
header can be used for
labels up to 6 inches long.
The actual label length is
calculated based on the
position of the last plotted
row in the image buffer.
x
X starting position for label. Older
printers used this parameter to
position labels horizontally so two
labels could be printed side-by-side.
Always set x equal to zero in any
printers that support the MULTIPLE
command. High speed Barcode
Blaster printers automatically limit
their print speed to 3 IPS when x is
nonzero.
dottime
Determines how long the printhead
dots stay hot, thereby changing the
dot length. Values can range from 0
to 255, but values less than 30 are
treated as 30. The dot time will
increment in steps of 10 when
operating in linear dot time mode
(see the VARIABLE MODE