User`s guide

PRINTER SETUP
148 Copyright © 2006, Cognitive.
VARIABLE ENERGY
Function The printer maintains a fixed energy density of 200
mJoules independent of print speed. This command
adjusts the energy density (in units of mJoules). It
is intended to be used to compensate for media that
requires more or less energy to create images of the
proper optical density. VARIABLE DARKNESS
may be used by the customer, but this command is
intended to be an easier to use, more precise optical
density control command for the C-series printer.
Explicit Form
Implicit Form
VARIABLE ENERGY energylevel/?
V energylevel/?
Parameters
Comments
Example
lLongStackCount 0 (query form) or 1
lpLongStack[0] energylevel (EnergyRange)
FUNCID=VARENERGYID=170
NOBUFFER
ImpUserEnergy