User`s guide
STORING DATA IN THE PRINTER MEMORY
98 Copyright © 2006, Cognitive.
Format Recall
Function Recalls a stored format from memory, merges any
incoming variable data with the stored data, and
prints labels as required.
NOTE: This command replaces the normal header line.
Do not use any other commands, including the END
command, with this command.
Explicit Form
!R t identifier x 100 maxY numlabels
Parameters
t
Data types. Use F for standard
ASCII format files and E for
enhanced format files.
NOTE: When recalling stored formats,
use the same value for t as was used
when the format was stored.
Specifying the wrong data type when
recalling a stored format may cause
the label to print incorrectly.
identifier
Object identifier assigned when the
object was stored.
Comments If variable data is needed to print the finished label,
the printer will expect the required data to follow
the Format Recall command. A carriage return or
carriage return and line feed must precede the
variable data.
See also Header line
Example The following example assumes that the label
format FORM_1 shown in the Format Store
example is already stored in the printer.
!R F FORM_1 0 100 170 1
MEN'S DRESS SHIRT
$17.85
SHIRT/$17.85