Instruction manual

4. Lamp: Installation
CF ZOOM AL utilises a Philips Fabolux 500W 55V lamp with a
and replacement GX 9,5 lampbase
The lamp is available from your authorised coemar sales agent:
coemar cod. 105071
wattage 500 W
luminous flux 11.880lm
colour temperature 3200° K
base GX 9,5
approximate life 200 hours
The fixture’s internal temperature can reach 250° C after 5 minutes, with a maximum
peak of 350° C; ensure that the lamp is cold prior to attempting removal. The fixture
should be allowed to stand and cool for 10 minutes prior to its removal.
The lamp is part of the tungsten halogen family of incandescent lamps and must be
handled with great care. The lamp operates at high temperature, and the slight risk
of explosion of the lamp exists if operated over its recommended life of 200 hours.
We recommend, therefore, that the lamp be replaced within the manufacturer’s spe-
cified lamp life.
mounting the lamp
1) Using a 3mm hex (Allen) key, remove the two hex bolts (A) which affix the lamp
assembly to the rear of the projector.
2) Remove the lamp assembly (B).
Attention
Turn off the power prior to opening up the unit.