Instruction manual

2) Press the enter button to confirm your selection; the display will show a numeri-
cal value which corresponds to the factory preset.
3) Press the + or button until the numerical value corresponds to the perfect align-
ment of the yellow colour in the optical path of the projector.
4) Press the enter button to confirm your selection.
FiAL
1) Press the + or button until the display shows FiAL (for alignment of the beam
shaping filter effects wheel).
2) Press the enter button to confirm your selection; the display will show a numeri-
cal value which corresponds to the factory preset.
3) Press the + or button until the numerical value corresponds with the correct ali-
gnment of the beam shaping effects wheel in the optical path of the projector.
4) Press the enter button to confirm your selection.
rcoL
1) Press the + or button until the display shows rcol (for alignment of the colour
wheel).
2) Press the enter button to confirm your selection; the display will show a numeri-
cal value which corresponds to the factory preset.
3) Press the + or button until the numerical value corresponds with the correct ali-
gnment of the colour wheel in the optical path of the projector.
4) Press the enter button to confirm your selection.
diMM
1) Press the + or button until the display shows diMM (for dimmer preheating).
2) Press the enter button to confirm your selection; the display will show a numeri-
cal value which corresponds to the factory preset.
3) Press the + or button until you have reached a minimum level of output from
the fixture when channel 5 is at 0. This procedure allows for lamp life to be pro-
longed by maintaining the filament of the lamp in a state of preheating thus avoi-
ding thermal shock to the filament.
4) Press the enter button to confirm your selection.
END
1) Press the + or button until the display shows END (for completion of the elec-
tronic alignment procedure)
2) Press the enter button to confirm your selection. The display will revert to its nor-
mal operating mode and the internal memory will record all changes made.
Important Note: At the termination of the above electronic calibration procedure,
if the END function is not performed, no memory changes will be effected. This
allows the operator to abort any changes made, in case of operator error.
function display
function display
function display
function display