Instruction manual

resetting the lamp life counter
The lamp life counter needs to be reset to zero at every lamp change to provide
accurate information on lamp life
1) Turn off the projector
2) Power up the CF ZOOM AL whilst simultaneously holding down the + and
buttons.
3) Press the menu button.
4) Press the + or - button until the display shows LIFE (for lamp life).
5) Press the enter button to confirm your selection; the display will show 0000 con-
firming that the counter has been reset.
disp
This function inverts the led display panels output. This allows for the display panel to
be easily read whether the unit is operated as a floor mounted fixture, or being
hung (see section 6. “Mounting the unit”).
1) Press the menu button.
2) Press the + or - button until the display shows diSP (for display).
3) Press the enter button to confirm your selection; the display will show AA (for
hanging fixture installation).
4) Press the + or - button the display will show (for floor mounted installation).
5) Press the enter button after either step 3 or 4 to confirm your choice of display mode.
dirp
This function inverts the movement for horizontal (pan) movements.
1) Press the menu button.
2) Press the + or - button until the display shows dirP (for pan direction).
3) Press the enter button to confirm your selection; the display will show cW (for
clockwise).
function display
function display
function display
AA
function display
function display
function display