Instruction manual
Mains connection
cabling
The mains cable provided is thermally resistant, complying to the most recent
international standards. It meets or exceeds the VDE and IEC norms, IEC 331,
IEC 332 3C,CEI 20 35.
NB: In case of cable replacement, similar cable with comparable thermal resistant quali-
ties must be used exclusivelly (cable 3x1.5 ø external 10 mm, rated 300/500V, tested
to 2KV, operating temperature -40° +180°, coemar cod. CV5309).
mains connection
The CF ZOOM AL can operate at voltages from 208V-230V-240V at 50 or 60Hz
(operating voltage and frequency can be selected as described in section 5 of this
manual).
Prior to connecting the unit to your mains supply, ensure that the model in your pos-
session correctly matches the mains supply available to you.
For connection purposes, ensure your plug is of a suitable rating: 3,5 amps.
Locate the mains cable which exits the base of the unit and connect as shown
below:
protection
The use of a thermal magnetic circuit breaker is recommended for each CF ZOOM AL.
A good earth connection is essential for the correct operation of the fixture. Strict
adherance to regulatory norms is strongly recommended.
marrone - brown
blu - blue
giallo/verde - yellow/green
marrone - brown
blu - blue
giallo/verde - yellow/green
massa
ground
neutro
neutral
fase
phase
alimentazione
main
marrone - brown
blu - blue
giallo/verde - yellow/green