8. Signal connection Control signal is digital, and is transmitted via two pair screened ΓΈ0.5mm cable.
Connection is serial, utilising XLR 3 or XLR5 male and female sockets located on the
base of the CF 1200 Hard Edge, labeled DMX 512 and DMX 512 standard
(see diagram).
Pin connections conform to the international standard:
pin 1= screening 0 volt pin 4= not connected
pin 2= data - pin 5= not connected
pin 3= data +
A connection using the 5 Pin XLR 5
3
2
1
Controller
Standard
DMX 512
OUT
Ad altri CF 1200 Hard Edge
Connect to other CF 1200 Hard Edge
in
out
in
out