Controlling CYBERLIGHT via the MA-Scancommander (Vers. 4.31)
1. Changing from Light Wave Research protocol to DMX 512
DMX input is via a 3pin XLR connector, where pin 1 to 3 correspond to pin 1 to 3 of the 5 pin XLR connector
of standard DMX 512. Pin 4 and 5 of the DMX connector are not used.
Attention: the pin order at the 3 pin connector is 1-3-2, whereas the 5 pin connector shows 1-2-3-4-5.
All personality switches stay 0, just setting address switch 8 to on will change to DMX.
2. DMX address
Unlike Trackspot or Intellabeam, the Cyberlight DMX address is set like on Lightwave Research protocol,
switch 8 always has to be on for DMX 512.
Switch 1 to 8 = 0 0 0 0 0 0 0 1 =lamp 1 DMX adress 1
1 0 0 0 0 0 0 1 =lamp 2 DMX adress 21
0 1 0 0 0 0 0 1 =lamp 3 DMX adress 41
1 1 0 0 0 0 0 1 =lamp 4 DMX adress 61
0 0 1 0 0 0 0 1 =lamp 5 DMX adress 81 ....
3. Accessing the Control Channel
The Control function can be addressed via the SPECIAL function in the SPEED menu of the Scancommander.
- Select one or more scans via the SCAN SELECTION buttons
Controlling the lamp is done in three steps:
-Step 1: Dimmer channel at full (FF)
Special channel at full (FF)
-Step 2: Dimmer channel at Zero (00)
Special channel at full (FF)
-Step 3: (must occur within 3 seconds)
Dimmer channel at Zero (00)
Special channel at 25% (3F) for "Home"
or Special channel at 50% (7F) for "Shutdown"
As this three steps have to be done within 3 seconds, please store this settings as presets (see cap 3.2.2 of
the Scancommander manual). The brightness Master of this scans have to be up during this steps.
After further 3 seconds the scans should start the selected function.