User`s guide

Emulation Manual
15Modify a Cuelist
Cue properties
The following properties can be set per cue:
Label
The label is the name of the CUE for your reference.
Condition
The condition species when the cue will be triggered. There are 3 possible Conditions:
Halt: The cue will be triggered when you press the GO button.
Follow: The cue will be triggered as soon as the previous cue has nished fading.
Wait: The cue will be triggered immediately after the previous cue has been triggered.
Cue Timing
To explain the dierent timings in combination with the Cue Condition, see the following diagram:
Cue 2
Starts fading
Delay
Fade in
Fade out
INTENSITY
100%
0%
INTENSITY
100%
0%
Cue 2
Starts fading
Delay
Fade in
Fade out
INTENSITY
100%
CUE 1
0%
INTENSITY
100%
CUE 2
Wait
0%
CUE 1
CUE 2
Follow
Condition Follow Condition Wait
Delay
The delay time (in seconds) is the time between the cue being triggered, and the cue actually starting to fade.
Fade in
The Fade In time (in seconds) is the fade time for all dimmers fading in (dimmer values going UP) in the cue and all other
fading attributes (e.g. colour mix, position).
Fade out
The Fade Out time (in seconds) is the fade time for all dimmers fading out (dimmer values going DOWN) in the cue.
Click and drag to select multiple properties for multiple cues, e.g. fade in for multiple cues or delay & fade in for multiple cues